3 maintenance tips for Debon pellet machine gearbox
First, replace the lubricating oil regularly
According to the product manual of Debon pellet machine
When using the equipment for the first time, it is necessary to add high-quality brand CK C320 medium-load industrial closed gear lubricating oil to the reducer
Change lubricating oil for the first time
Must be replaced after 450 hours of operation
The second time and after
You can judge the replacement time by observing the turbidity of the lubricating oil through the reducer oil level.
Through observation, if the lubricating oil is gray and dark,
it means that the lubricating oil is turbid and needs to be replaced in time.
If the lubricating oil is clear, it is also recommended to replace it after every 1500 hours.
Second, check the elastic coupling regularly
The elastic coupling protects the motor and reducer
According to the product manual, it should be checked every 1500 hours or replaced directly
Lift the main motor during inspection
Pick up the elastic coupling and observe carefully
Check the whole part
If there is any deformation or damage, please replace it in time.
Third, clean the oil suction filter regularly.
According to the product manual, the oil suction filter needs to be cleaned every 450 hours.
When cleaning, remove the oil suction filter, soak it in gasoline for a while, or blow it clean with an air pump, remove the sticky substances on the filter, and install it again.
A good equipment
If you want it to run healthily all the time
We must pay attention to its later maintenance and care
to use it for a longer time
If you want to inspect the large-scale dense molding production line equipment
Zhengzhou Debon welcomes you to visit the factory